Using Home Assistant sensors as the input source

Home Assistant sensors can be used as the input source. To access the sensors, you have to create an access token in Home Assistant and configure the uni-meter with that access-token and the URL of your system.

Also, with this input, the input source can operate in two modes. Either in a mono-phase mode, where the power and/or the energy data is provided as a single value for all three phases, or in a tri-phase mode, where the power and/or the energy data is provided as a separate value for each phase.

Depending on the chosen phase mode, the sensors to be used can be configured by the following properties:

  • Power mono-phase
    • power-sensor - sensor providing the total current power
  • Power tri-phase
    • power-l1-sensor - sensor providing current power phase 1
    • power-l2-sensor - sensor providing current power phase 2
    • power-l3-sensor - sensor providing current power phase 3
  • Energy mono-phase
    • energy-consumption-sensor - sensor providing total energy consumption
    • energy-production-sensor - sensor providing total energy production
  • Energy tri-phase
    • energy-consumption-l1-sensor - sensor providing energy consumption phase 1
    • energy-consumption-l2-sensor - sensor providing energy consumption phase 2
    • energy-consumption-l3-sensor - sensor providing energy consumption phase 3
    • energy-production-l1-sensor - sensor providing energy production phase 1
    • energy-production-l2-sensor - sensor providing energy production phase 2
    • energy-production-l3-sensor - sensor providing energy production phase 3

If you have a setup where the power values are split up between power production and power consumption, you can additionally specify the sensors for the production.

  • Power mono-phase
    • power-production-sensor - sensor providing the current production power
  • Power tri-phase
    • power-production-l1-sensor - sensor providing current production power phase 1
    • power-production-l2-sensor - sensor providing current production power phase 2
    • power-production-l3-sensor - sensor providing current production power phase 3

The current power values are then calculated as

current power = power-sensor - power-production-sensor

or

current power Lx = power-Lx-sensor - power-production-lx-sensor

So the simplest /etc/uni-meter.conf file reading the data from Home Assistant sensors could look like this:

uni-meter {
  output = "uni-meter.output-devices.shelly-pro3em"

  input = "uni-meter.input-devices.home-assistant"

  input-devices {
    home-assistant {
      url = "http://192.168.178.51:8123"
      access-token = "eyJhbGciOiJIUzI1Ni...."

      power-phase-mode = "mono-phase"
      energy-phase-mode = "mono-phase"

      power-sensor = "sensor.current_power"
      energy-consumption-sensor = "sensor.energy_imported"
      energy-production-sensor = "sensor.energy_exported"
    }
  }
}