Release 3.4.0 (#10) # Release 3.4.0 ## New features - Possibility to add a prefix and postfix for write messages ## Improvements - Plain text search is used now for pattern search - Automatically set a pattern search within read message when selecting single process data or parameter - Improved handling if connecting SLT device
Release 3.1.0 (#7) # Release 3.1.0 ## New features - OnNewRawReadMessage_INSTANCE_PORT_MESSAGENAME provides timestamp as 2nd event parameter (used for FlowConfig) ## Improvements - Minor docu improvements - Minor update of readMessageName check ## Bugfix - DeviceID was shown as ProductID in UI - 'OnNewDataAuto' FlowConfig block did not work with initial load of persistent data - Legacy bindings of ValueDisplay elements and FileUpload feature within UI did not work if deployed with VS Code AppSpace SDK - UI differs if deployed via Appstudio or VS Code AppSpace SDK - Fullscreen icon of iFrame was visible
Release 3.0.0 (#4) # Release 3.0.0 ## New features - Provide features even without CSK_IODDInterpreter - Possibility to create readMessages without IODD information, by setting start-/endByte and unpack format - Possibility to search and cut relevant part out of created JSON within readMessage - New FlowConfig block 'OnNewDataAuto' which automatically creates readMessages and optionally checks to power selected port (WARNING: Do NOT mix with manual readMessage setup) - React on "OnStopFlowConfigProviders" event of FlowConfig modul to stop pulling IO-Link data - Check and handle different kind of IOLink.SMI APIs - Function to delete all existing readMessages - Check if persistent data to load provides all relevant parameters. Otherwise add default values - Selectable if timers for readMessages should start automatically after parameters were loaded ## Improvements - Changed event name "OnNewReadMessage_PORT_MESSAGENAME" to "OnNewReadMessage_INSTANCE_PORT_MESSAGENAME" to make it possible to switch between ports during runtime - Do not start readMessage timers automatically with creation of readMessage - Use new event 'OnNewRawReadMessage_INSTANCE_PORT_MESSAGENAME" within FlowConfig (only providing data content as first parameter) - If using FlowConfig, start readMessage timers after 5 seconds - Add info about port within "OnNewIOLinkPortStatus" event - Add list of ports related to instances within "getInstancePortMap" function - Better handling if CSK_IODDInterpreter is not available ## Bugfix - Issue with CSK_UserManagement support - Error if sending process data without any selection - Error in handling IODD data
# Release 2.0.0 (#2) # Release 2.0.0 ## New features - Supports FlowConfig feature to provide data of IO-Link ReadMessage - Changed event name of readMessages from 'readMessage[PORT][MESSAGENAME] to 'OnNewReadMessage_[PORT]_[MESSAGENAME] - Possible to pause timers for readMessages - Function 'getPort' for currently selected instance - Provide version of module via 'OnNewStatusModuleVersion' - Function 'getParameters' to provide PersistentData parameters - Check if features of module can be used on device and provide this via 'OnNewStatusModuleIsActive' event / 'getStatusModuleActive' function - Function to 'resetModule' to default setup ## Improvements - Better interaction with CSK_IODDInterpreter (version 2.0.0 needed) - Check status of port within instance thread (prevent to get data if sensor is not in operating mode) - Port only changeable if currently inactive - New UI design available (e.g. selectable via CSK_Module_PersistentData v4.1.0 or higher), see 'OnNewStatusCSKStyle' - Preset names for ReadMessages / WriteMessages instead of renaming them after creation - check if instance exists if selected - 'loadParameters' returns its success - 'sendParameters' can control if sent data should be saved directly by CSK_Module_PersistentData - Added UI icon and browser tab information ## Bugfix - IODD parsing - Check if readMessage exists before trying to delete it